AR01: The system will not work without internet connection.

AR02: The system will not guarantee face detection if the user is more than 1.5 meters away from the camera.

AR03: The system will not guarantee speech recognition if the user is more than 1.5 meters away from the microphone or ambient noise is greater than 50 dB.

AR04: The system will not guarantee proper detecting and recognition of objects if the illumination is less than 200 lux or greater than 2000 lux.

AR05: The system will not save the student progress if an unexpected power drop occurs.

AR06: The system will not guarantee expected response times if internet connection speed is below 50Mpbs.

AR07: The system will not guarantee proper functioning if OpenAi is facing outages.

AR08: The system will not guarantee proper functioning after being dropped or knocked over.

AR09: The system will not guarantee proper operation if any part of the system becomes wet.

AR10: The system will not guarantee proper functioning if someone restricts any of its movements by force (e.g. by hugging the system).

AR11: The system will not guarantee proper operation if connected to a power source other than the specified.

AR12: The system will not guarantee proper functioning if the microphone is being physically blocked.

AR13: The system will not guarantee proper operation if any of its parts are disassembled.

AR14: The system will not guarantee proper functioning if magnetic components are placed close to the compartment’s lock.

AR15: The graphical interface will not have a view dedicated for the student.